MARATHON PETROLEUM CO -- 1-K KEROSENE -- 9140-01-292-4460
=====================  Product Identification  =====================

Product ID:1-K KEROSENE
MSDS Date:05/16/1990
FSC:9140
NIIN:01-292-4460
=== Responsible Party ===
Company Name:MARATHON PETROLEUM CO
Address:539 S MAIN ST
City:FINDLAY
State:OH
ZIP:45840-3229
Country:US
Info Phone Num:419-422-2121
Emergency Phone Num:419-422-2121/800-424-9300(CHEMTREC)
CAGE:IO115
=== Contractor Identification ===
Company Name:AMERICAN SOCIETY FOR TESTING AND MATERIALS
Address:1916 RACE STREET
Box:City:PHILADELPHIA
State:PA
ZIP:19103
Country:US
CAGE:81346
Company Name:MARATHON OIL CO
Address:539 SOUTH MAIN STREET
Box:City:FINDLEY
State:OH
ZIP:45840-3229
Country:US
Phone:419-422-2121, CHEMTREC 800-424-9300
CAGE:16106
Company Name:MARATHON PETROLEUM CO
Address:539 SOUTH MAIN ST
Box:City:FINDLAY
State:OH
ZIP:45840
Country:US
Phone:419-422-2121
CAGE:IO115

=============  Composition/Information on Ingredients  =============

Ingred Name:KEROSENE
CAS:8008-20-6
RTECS #:OA5500000
Fraction by Wt: 100%
Other REC Limits:NONE SPECIFIED
OSHA PEL:100 PPM
ACGIH TLV:100 PPM 9091

Ingred Name:PARAFFINS & CYCLOPARAFFINS
Fraction by Wt: 70-80%
Other REC Limits:NONE SPECIFIED

Ingred Name:OLEFINS
Fraction by Wt: 3-6%
Other REC Limits:NONE SPECIFIED

Ingred Name:AROMATIC HYDROCARBONS
Fraction by Wt: 17-25%
Other REC Limits:NONE SPECIFIED
OSHA PEL:2000 MG/M3 (PER MFR)

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:EYE-LITTLE OR NO IRRITATION ON DIRECT
    CONTACT. SKIN-MAY PRODUCE SEVERE IRRITATION OR DERMATITIS.
    INGESTION-ASPIRATION OF VOMITUS INTO THE LUNGS MUST BE AVOIDED AS
    EVEN SMALL QUANTITIES IN THE LUNGS CA N PRODUCE CHEMICAL
    PNEUMONITIS AND PULMONARY EDEMA/HEMORRAGE.
Explanation of Carcinogenicity:THIS COMPOUND CONTAINS NO INGREDIENTS AT
    CONCENTRATIONS OF 0.1% OR GREATER THAT ARE CARCINOGENS OR SUSPECT
    CARCINOGENS.
Effects of Overexposure:SKIN-PROLONGED OR REPEATED LIQUID CONTACT CAN
    CAUSE DEFATTING AND DRYING OF THE SKIN. INHALATION-HIGH VAPOR
    CONCENTRATIONS MAY PRODUCE HEADACHE, GIDDINESS, VERTIGO AND
    ANESTHETIC STUPOR.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:EYES: FLUSH WITH RUNNING WATER FOR 15 MINUTES. IF IRRITATION
    OCCUR, CALL A PHYSICIAN. SKIN: WASH WITH SOAP AND WATER. REMOVE
    CONTAMINATED CLOTHING. CALL A PHYSICIAN. INHALATION: MOVE TO FRESH
    AIR. GIV E ARTIFICIAL RESPIRATION, IF NOT BREATHING. CALL A
    PHYSICIAN. INGESTION: DO NOT INDUCE VOMITING. DO NOT GIVE LIQUIDS.
    IMMEDIATELY CALL A PHYSICIAN.

=====================  Fire Fighting Measures  =====================

Flash Point:120F,49C
Lower Limits:0.7%
Upper Limits:5.0%
Extinguishing Media:CLASS B FIRE EXTINGUISHING MEDIA SUCH AS FOAM,
    CARBON DIOXIDE OR DRY CHEMICAL.
Fire Fighting Procedures:FIRE FIGHTING SHOULD BE ATTEMPTED ONLY BY
    THOSE WHO ARE ADEQUATELY TRAINED. WATER CAN BE USED TO COOL EXPOSED
    SURFACES.
Unusual Fire/Explosion Hazard:AVOID USE OF SOLID WATER STREAMS. AVOID
    EXCESSIVE WATER SPRAY APPLICATION.

==================  Accidental Release Measures  ==================

Spill Release Procedures:KEEP PUBLIC AWAY. SHUT OFF SOURCE. ELIMINATE
    IGNITION SOURCES. ADVISE NRC (800-424-8802) FOR WATER SPILL.
    CONTAIN LIQUID WITH SAND OR SOIL. RECOVER & RETURN FREE LIQUID TO
    SOURCE. USE SUITABLE SORBENT  TO CLEAN UP RESIDUAL LIQUIDS.

======================	Handling and Storage  ======================

Handling and Storage Precautions:PRODUCT SHOULD BE HANDLED & STORED IN
    ACCORDANCE WITH INDUSTRY ACCEPTED PRACTICES. IN THE ABSENCE OF
    LOCAL CODES REQUIREMENTS, USE NFPA OR OSHA CODES.
Other Precautions:USE APPROPIATE GROUNDING AND BONDING PRACTICES. STORE
    IN PROPERLY CLOSED CONTAINERS THAT ARE PROPERLY LABELED. DO NOT
    EXPOSE TO HEAT, OPEN FLAME, STRONG OXIDIZERS OR OTHER IGNITION
    SORCES. AVOID SKIN	CONTACT.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:APPROVED ORGANIC CHEMICAL CARTRIDGE OR SUPPLIED
    AIR RESPIRATOR SHOULD BE WORN WHEN EXCESSIVE VAPORS OR MISTS ARE
    GENERATED. OBSERVE RESPIRATOR PROTECTION FACTOR CRITERIA CITED IN
    ANSI Z88.2 1980. SCBA  SHOULD BE USED FOR FIRE FIGHTING.
Ventilation:LOCAL OR GENERAL EXHAUST REQUIRED WHEN SPRAYING OR USING AT
    ELEVATED TEMPERATURES.
Protective Gloves:NEOPRENE, NITRILE OR PVC GLOVES
Eye Protection:SAFETY GLASSES - CHEMICAL SPLASH GOGGLES
Other Protective Equipment:USE MECHANICAL VENTILATION EQUIPMENT THAT IS
    EXPLOSION-PROOF.
Work Hygienic Practices:EXERCISE GOOD PERSONAL HYGIENE INCLUDING
    REMOVAL OF SOILED CLOTHING AND PROMPT WASHING WITH SOAP AND WATER.
Supplemental Safety and Health
WARNING! COMBUSTIBLE LIQUID. HARMFUL OR FATAL IF SWALLOWED. PRODUCES
    SKIN IRRITATION UPON PROLONGED OR REPEATED CONTACT.

==================  Physical/Chemical Properties  ==================

HCC:F4
Boiling Pt:B.P. Text:350-570F
Vapor Pres:1-10 MMHG
Vapor Density:4-5 AIR=1
Spec Gravity:0.8
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR OR AMBER LIQUID. FUEL OIL ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:THIS MATERIAL IS STABLE AT 70F. 760 MM
    PRESSURE.
Hazardous Decomposition Products:CARBON MONOXIDE, ALDEHYDES, AROMATICS,
    OTHER HYDROCARBONS.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF CLEANUP MATERIAL IN ACCORDANCE WITH
    APPLICABLE LOCAL, STATE AND FEDERAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.