FIRE RESEARCH LABORATORIES -- CLEARCOAT -- 8010-00N064870
=====================  Product Identification  =====================

Product ID:CLEARCOAT
MSDS Date:03/10/1994
FSC:8010
NIIN:00N064870
=== Responsible Party ===
Company Name:FIRE RESEARCH LABORATORIES
Address:5364 PAN AMERICAN FREEWAY NE
City:ALBUQUERQUE
State:NM
ZIP:87109
Country:US
Info Phone Num:800-877-3473
Emergency Phone Num:800-424-9300(CHEMTREC)
CAGE:OUH50
=== Contractor Identification ===
Company Name:FIRE RESEARCH LABORATORIES
Box:9645
City:ALBUQUERQUE
State:NM
ZIP:87119-9645
Country:US
Phone:505-883-8433
CAGE:0FWV2
Company Name:FIRE RESEARCH LABORATORIES
Address:5364 PAN AMERICAN FWY NE
Box:9645
City:ALBUQUERQUE
State:NM
ZIP:67102
Country:US
Phone:505-883-8433;800-877-3473
CAGE:OUH50

=============  Composition/Information on Ingredients  =============

Ingred Name:NON-HAZARDOUS INGREDIENTS
OSHA PEL:N/K 
ACGIH TLV:N/K 

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:EFTS FROM ROUTINE USE:PROD DOES NOT
    PRESENT ANY SIGNIFICANT HAZS TO HLTH WHEN HNDLD ACCORDING TO STD
    INDUST PRACT. EFTS OF OVEREXP:VAPOR OR MIST MIGHT POSSIBLY CAUSE
    HEADACHE, NAUSEA, AND IRRITATION O F THE NOSE, THROAT AND LUNGS AT
    VERY HIGH CONCENTRATIONS. CAN BE IRRITATING TO SKIN UPON REPEATED
    OR (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZS:PROLONGED CONTACT. SLIGHTLY
    IRRITATING TO EYES UPON CONTACT. HIGH CONCENTRATIONS OF VAPOR MAY
    CAUSE LIGHT-HEADEDNESS, DROWSINESS AND MAY AGGRAVATE SYMPTOMS
    ASSOCIATED WITH PRE-EXISTING LUNG  DISORDERS.
Medical Cond Aggravated by Exposure:MAY AGGRAVATE SYMPTOMS ASSOCIATED
    WITH PRE-EXISTING LUNG DISORDERS.

=======================  First Aid Measures  =======================

First Aid:INHALATION:REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE
    O*2/ARTF RESP) . EYES:FLUSH WITH COPIOUS AMOUNTS OF WATER FOR AT
    LEAST 15 MINUTES. CONSULT A PHYSICIAN IF IRRITATION PERSISTS.
    SKIN:FLUSH	WITH COPIOUS AMOUNTS OF WATER FOR AT LEAST 15 MINUTES.
    CONSULT A PHYSICIAN IF IRRITATION PERSISTS. REMOVE CONTAM CLTHG.
    INGESTION:DILUTE WITH ONE TO TWO GLASSES OF WATER, IF CONSCIOUS.
    CONSULT MD.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
    PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NON-COMBUSTIBLE, MAY SPLATTER ABOVE 100C.
    CURED POLYMER FILM MAY BURN UNDER EXTREME CONDITIONS.

==================  Accidental Release Measures  ==================

Spill Release Procedures:KEEP SPECTATORS AWAY. FLOOR MAY BE SLIPPERY.
    DIKE & CNTN SPILL W/INERT MATL (E.G. SAND, VERMICULITE). TRANSFER
    USED ABSORB & DIKING MATLS TO CNTNRS FOR RECOVERY/DISP. KEEP SPILLS
    & CLEANING RUNOFFS OU T OF MUNICIPAL SEWERS & OPEN BODIES OF WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE CONTAINER OUT OF SUN AND AWAY
    FROM HEAT SOURCES. KEEP CONTAINERS CLOSED WHEN NOT IN USE.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH/MSHA APPROVED CHEMICAL (CARTRIDGE) FILTERS
    DESIGNED TO REMOVE VAPORS.
Ventilation:MECHANICAL EXHAUST VENTILATION AT POINT OF VAPOR OR MIST
    RELEASE.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPROVED EMERGENCY EYE WASH AND DELUGE
    SHOWER .
Work Hygienic Practices:WASH THOROUGLY AFTER HANDLING.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

==================  Physical/Chemical Properties  ==================

Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:AVOID TEMPERATURES ABOVE 175C.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF SOLIDIFIED WASTES IN ACCORDANCE WITH
    FEDERAL, STATE AND LOCAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.