DIAMANT METALLPLASTIC GMBH -- HARDENER -- 8040-00N021107
===================== Product Identification =====================
Product ID:HARDENER
MSDS Date:10/19/1987
FSC:8040
NIIN:00N021107
Kit Part:Y
=== Responsible Party ===
Company Name:DIAMANT METALLPLASTIC GMBH
Address:12 HONTZLARSTR
City:D 4050 MOENCHENGLADBACH 2 WEST GERMANY
Info Phone Num:02166-86002
Emergency Phone Num:02166-86002
CAGE:DIAMA
=== Contractor Identification ===
Company Name:DIAMANT METALLPLASTIC GMBH
Address:12 HONTZLARSTR
Box:City:D 4050 MOENCHENGLADBACH 2 WEST GERMANY
Phone:02166-86002
CAGE:DIAMA
============= Composition/Information on Ingredients =============
Ingred Name:ALIPHATIC POLYAMINES; (MIXTURE CONTAINING INGREDIENT 2)
Ingred Name:PHENOL
CAS:108-95-2
RTECS #:SJ3325000
Fraction by Wt: <5%
OSHA PEL:5 PPM, S
ACGIH TLV:5 PPM, S
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ingred Name:TALC (POWDER), CONTAINING NO ASBESTOS FIBERS; (TALCUM)
CAS:14807-96-6
RTECS #:WW2710000
OSHA PEL:20 MPPCF
ACGIH TLV:2 MG/M3 RDUST
Ingred Name:MOLYBDENUM DISULFIDE
CAS:1317-33-5
RTECS #:QA4697000
OSHA PEL:5 MG MO/M3
ACGIH TLV:5 MG MO/M3
Ingred Name:GRAPHITE
CAS:7782-42-5
RTECS #:MD9659600
OSHA PEL:15 MPPCF; Z-3
ACGIH TLV:2 MG/M3 RDUST
===================== Hazards Identification =====================
LD50 LC50 Mixture:LD50: (ORAL,RAT): 1000 MG/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:MODERATE SKIN IRRITATION, SEVERE EYE
IRRITATION POSSIBLE. PHENOL CAN BE ABSORBED THROUGH SKIN;
INHALATION OF LARGER AMOUNTS CAN IRRITATE RESPIRATORY DUCTS.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:EYES: IRRIGATE WITH WATER FOR AT LEAST 15 MINUTES, GET
MEDICAL ATTENTION. INHALATION: IN CASE OF PROBLEMS GET TO FRESH
AIR, GET MEDICAL ATTENTION. INGESTION: GET IMMEDIATE MEDICAL
ATTETNION. SKIN: WAS H OFF WITH WATER AND SOAP, CHANGE SOILED
CLOTHING.
===================== Fire Fighting Measures =====================
Flash Point Method:PMCC
Flash Point:244F,118C
Extinguishing Media:H2O MIST, CO2, FOAM DRY POWDER.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE KNOWN.
================== Accidental Release Measures ==================
Spill Release Procedures:WIPE UP WITH PAPER TOWELS OR ABSORBENT
MATERIALS (SKIN & RESPIRATION PROTECTION!).
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:AS DESCRIBED, AVOID SKIN CONTACT, USE
RESPIRATION PROTECTION WHERE APPLICABLE.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:WELL VENTILATED WORK AREAS ARE GENERALLY
SUFFICIENT. USE NIOSH/MSHA APPROVED SPECIAL RESPIRATORY PROTECTION
IN SMALLER, CONFINED ROOMS.
Ventilation:LOCAL EXHAUST RECOMMENDED. MECHANICAL EXHAUST ACCEPTABLE.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:CLOTHING WITH LONG LEGS AND SLEEVES.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
================== Physical/Chemical Properties ==================
HCC:N1
Boiling Pt:B.P. Text:>572F,>300C
Vapor Pres:<0.01
Spec Gravity:1
Solubility in Water:NO
Appearance and Odor:LIQUID OF DARK-RED COLOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CO, CO2, NITROGEN OXIDES ON BURNING.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSAL METHODS BASED ON FEDERAL, STATE AND
LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.